{"id":21184,"date":"2020-03-20T06:00:37","date_gmt":"2020-03-20T06:00:37","guid":{"rendered":"https:\/\/www.igt.nl\/product\/ams-p\/"},"modified":"2025-11-12T12:47:32","modified_gmt":"2025-11-12T12:47:32","slug":"ams-p","status":"publish","type":"product","link":"https:\/\/www.igt.nl\/sg\/product\/ams-p\/","title":{"rendered":"Amsterdam P"},"content":{"rendered":"<p>Automated printability tester with single printing shaft dedicated to the Pick test.<\/p>\n<p>IGT Amsterdam family are a new range of Printability testers with integrated, camera based, analysis systems. The range consists of testers with one to six printing shafts for maximum flexibility of test methods. The long range of test methods can be extended with user defined methods. With that it is capable to perform all tests of a Global Standard Tester P plus the tests of a Global Standard Tester 3, including combinations of constant and increasing speed in one test method.<\/p>\n<p>IGT Amsterdam P is especially designed for QC purposes, it is prepared to do in-line analysis of pick ISO 3783. Additionally mottling, Heliotest, print penetration, IGT roughness and hydro-expansivity with a camera based analysis system.<\/p>\n<ul>\n<li>1 to 6 printing shafts, each can be equipped with a drive for printing in register if needed<\/li>\n<li>Very small interval times, up from 0,02 s<\/li>\n<li>Large number of test methods<\/li>\n<li>Very easy in operation<\/li>\n<li>In-line analysis of several test methods<\/li>\n<li>Export of scanned images and results<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Automated multi-purpose printability tester with single printing shaft dedicated to the Pick test; including analysis software and camera.<\/p>\n","protected":false},"featured_media":21185,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"product_brand":[],"product_cat":[1766,1769],"product_tag":[],"class_list":{"0":"post-21184","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-amsterdam-sg","7":"product_cat-paper-testers-sg","8":"product_shipping_class-normaal-sg","9":"pa_accessories-different-printing-discs-for-several-applications-sg","10":"pa_accessories-gravure-set-sg","11":"pa_accessories-heliotest-set-sg","12":"pa_accessories-hydro-expansivity-set-sg","13":"pa_accessories-intaglio-inking-set-sg","14":"pa_accessories-loose-and-weakly-bound-particles-set-fluff-sg","15":"pa_accessories-picktest-set-sg","16":"pa_accessories-westvaco-pick-test-set-sg","17":"pa_additional-items-408-000-200-igt-ink-pipette-0-01-ml-resolution-sg","18":"pa_additional-items-408-000-400-igt-ink-pipette-0-001-ml-resolution-sg","19":"pa_additional-items-441-000-pick-start-viewer-psv-sg","20":"pa_additional-items-466-000-000-high-speed-inking-unit-4-sg","21":"pa_analysis-options-pick-iso-3783-sg","22":"pa_analysis-options-yes-sg","23":"pa_camera-yes-sg","24":"pa_compatible-instruments-722-000-000-amsterdam-2-sg","25":"pa_compatible-instruments-725-000-000-amsterdam-5-sg","26":"pa_compatible-instruments-726-000-000-amsterdam-6-sg","27":"pa_conformance-with-standards-astm-7680-sg","28":"pa_conformance-with-standards-iso-2834-sg","29":"pa_conformance-with-standards-iso-2836-sg","30":"pa_conformance-with-standards-iso-2846-sg","31":"pa_conformance-with-standards-iso-3783-2006-sg","32":"pa_data-export-options-recording-and-export-of-images-settings-and-analysis-results-via-usb-sg","33":"pa_dimensions-d-x-w-x-h-cm-59-x-50-x-64-sg","34":"pa_dispensing-system-if-necessary-this-will-be-delivered-in-accessories-set-sg","35":"pa_doctoring-system-standard-at-print-shaft-1-sg","36":"pa_forces-100-1000-n-in-steps-of-1-n-sg","37":"pa_guarantee-standard-one-year-sg","38":"pa_inks-or-liquids-density-test-ink-sg","39":"pa_inks-or-liquids-intaglio-ink-sg","40":"pa_inks-or-liquids-penetration-liquid-sg","41":"pa_inks-or-liquids-pick-test-ink-sg","42":"pa_inks-or-liquids-pick-test-oil-sg","43":"pa_inks-or-liquids-roughness-liquid-sg","44":"pa_inks-or-liquids-set-off-ink-sg","45":"pa_interfaces-usb-portal-sg","46":"pa_interval-time-and-number-1-600-s-in-steps-of-1-s-sg","47":"pa_lifting-system-automatically-sg","48":"pa_maintenance-yearly-sg","49":"pa_maintenance-information-can-be-obtained-from-your-supplier-or-the-local-agent-sg","50":"pa_maintenance-the-annual-maintenance-and-calibration-of-the-tester-can-be-carried-out-by-igt-testing-systems-or-companies-authorized-by-igt-testing-systems-sg","51":"pa_nr-of-doctoring-systems-1-sg","52":"pa_nr-of-printing-shafts-1-sg","53":"pa_power-supply-requirements-115-v-50-60-hz-or-230-v-50-60-hz-sg","54":"pa_pre-programmed-tests-custom-made-tests-on-request-sg","55":"pa_pre-programmed-tests-density-colour-and-transparency-sg","56":"pa_pre-programmed-tests-gravure-sg","57":"pa_pre-programmed-tests-heliotest-sg","58":"pa_pre-programmed-tests-hydroexpansivity-sg","59":"pa_pre-programmed-tests-igt-roughness-sg","60":"pa_pre-programmed-tests-pick-sg","61":"pa_pre-programmed-tests-print-penetration-sg","62":"pa_pre-programmed-tests-toner-adhesion-sg","63":"pa_print-length-and-width-mm-10-550-length-sector-dependent-depends-on-printing-form-and-test-method-sg","64":"pa_print-length-and-width-mm-5-50-mm-wide-sg","65":"pa_printing-discs-aluminium-sg","66":"pa_printing-discs-discs-for-specific-test-sg","67":"pa_printing-discs-gravure-sg","68":"pa_printing-discs-heliotest-sg","69":"pa_printing-discs-rubber-sg","70":"pa_printing-discs-rubber-blanket-sg","71":"pa_sector-positioning-automatically-sg","72":"pa_sector-positioning-programmable-sg","73":"pa_sector-type-and-options-180-sector-with-clamps-sg","74":"pa_sector-type-and-options-360-sector-without-clamps-with-different-coverages-sg","75":"pa_shaft-positioning-automatically-sg","76":"pa_shaft-positioning-programmable-sg","77":"pa_software-updates-via-usb-sg","78":"pa_space-requirements-0-7-m-sg","79":"pa_speed-range-and-modes-accelerating-end-speed-0-1-4-0-m-s-in-steps-of-0-1-m-s-sg","80":"pa_speed-range-and-modes-constant-speed-0-1-4-0-m-s-in-steps-of-0-1-m-s-sg","81":"pa_substrate-requirements-flexible-substrates-sg","82":"pa_test-method-colour-densitiy-ink-transfer-w46-sg","83":"pa_test-method-fluff-w33-sg","84":"pa_test-method-gravure-180-w67-sg","85":"pa_test-method-gravure-360-w73-sg","86":"pa_test-method-halftone-printing-w45-sg","87":"pa_test-method-heliotest-w41-sg","88":"pa_test-method-hydro-expensivity-w89-sg","89":"pa_test-method-igt-roughness-w28-sg","90":"pa_test-method-intaglio-w85-sg","91":"pa_test-method-linting-w44-sg","92":"pa_test-method-pick-igt-iso-3783-w31-sg","93":"pa_test-method-pick-offset-delammination-w65-w75-sg","94":"pa_test-method-pick-passestofail-index-curve-w86-w87-w88-sg","95":"pa_test-method-pick-westvaco-w38-sg","96":"pa_test-method-print-gloss-w49-sg","97":"pa_test-method-print-penetration-w24-sg","98":"pa_test-method-print-smoothness-w77-sg","99":"pa_test-method-rubber-blanket-ink-absorption-w61-sg","100":"pa_test-method-rubber-blanket-roughness-w62-sg","101":"pa_test-method-strike-through-w43-sg","102":"pa_test-method-toner-adhesion-constant-speed-w55-sg","103":"pa_test-method-toner-adhesion-increasing-speed-w56-sg","104":"pa_weight-110-kg-sg","106":"first","107":"instock","108":"featured","109":"shipping-taxable","110":"purchasable","111":"product-type-simple"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Amsterdam P - IGT Testing Systems<\/title>\n<meta name=\"description\" content=\"IGT Amsterdam P is especially designed for QC purposes, it is prepared to do in-line analysis of Pick: IGT ISO 3783. Additionally IGT Roughness.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.igt.nl\/sg\/product\/ams-p\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Amsterdam P - IGT Testing Systems\" \/>\n<meta property=\"og:description\" content=\"IGT Amsterdam P is especially designed for QC purposes, it is prepared to do in-line analysis of Pick: IGT ISO 3783. Additionally IGT Roughness.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.igt.nl\/sg\/product\/ams-p\/\" \/>\n<meta property=\"og:site_name\" content=\"IGT Testing Systems\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-12T12:47:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.igt.nl\/wp-content\/uploads\/721.000_AMS-P_rvs_1-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"700\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/product\\\/ams-p\\\/\",\"url\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/product\\\/ams-p\\\/\",\"name\":\"Amsterdam P - IGT Testing Systems\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/product\\\/ams-p\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/product\\\/ams-p\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.igt.nl\\\/wp-content\\\/uploads\\\/721.000_AMS-P_rvs_1-1.jpg\",\"datePublished\":\"2020-03-20T06:00:37+00:00\",\"dateModified\":\"2025-11-12T12:47:32+00:00\",\"description\":\"IGT Amsterdam P is especially designed for QC purposes, it is prepared to do in-line analysis of Pick: IGT ISO 3783. Additionally IGT Roughness.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/product\\\/ams-p\\\/#breadcrumb\"},\"inLanguage\":\"sg-SG\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.igt.nl\\\/sg\\\/product\\\/ams-p\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sg-SG\",\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/product\\\/ams-p\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.igt.nl\\\/wp-content\\\/uploads\\\/721.000_AMS-P_rvs_1-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.igt.nl\\\/wp-content\\\/uploads\\\/721.000_AMS-P_rvs_1-1.jpg\",\"width\":700,\"height\":700},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/product\\\/ams-p\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Paper Testers\",\"item\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/product-categorie\\\/paper-testers-sg\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Amsterdam\",\"item\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/product-categorie\\\/paper-testers-sg\\\/amsterdam-sg\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Amsterdam P\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/#website\",\"url\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/\",\"name\":\"IGT Testing Systems\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sg-SG\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/#organization\",\"name\":\"IGT Testing Systems\",\"url\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sg-SG\",\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.igt.nl\\\/wp-content\\\/uploads\\\/logo-igt-nieuw-450.webp\",\"contentUrl\":\"https:\\\/\\\/www.igt.nl\\\/wp-content\\\/uploads\\\/logo-igt-nieuw-450.webp\",\"width\":451,\"height\":61,\"caption\":\"IGT Testing Systems\"},\"image\":{\"@id\":\"https:\\\/\\\/www.igt.nl\\\/sg\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Amsterdam P - IGT Testing Systems","description":"IGT Amsterdam P is especially designed for QC purposes, it is prepared to do in-line analysis of Pick: IGT ISO 3783. Additionally IGT Roughness.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.igt.nl\/sg\/product\/ams-p\/","og_locale":"en_US","og_type":"article","og_title":"Amsterdam P - IGT Testing Systems","og_description":"IGT Amsterdam P is especially designed for QC purposes, it is prepared to do in-line analysis of Pick: IGT ISO 3783. Additionally IGT Roughness.","og_url":"https:\/\/www.igt.nl\/sg\/product\/ams-p\/","og_site_name":"IGT Testing Systems","article_modified_time":"2025-11-12T12:47:32+00:00","og_image":[{"width":700,"height":700,"url":"https:\/\/www.igt.nl\/wp-content\/uploads\/721.000_AMS-P_rvs_1-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.igt.nl\/sg\/product\/ams-p\/","url":"https:\/\/www.igt.nl\/sg\/product\/ams-p\/","name":"Amsterdam P - IGT Testing Systems","isPartOf":{"@id":"https:\/\/www.igt.nl\/sg\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.igt.nl\/sg\/product\/ams-p\/#primaryimage"},"image":{"@id":"https:\/\/www.igt.nl\/sg\/product\/ams-p\/#primaryimage"},"thumbnailUrl":"https:\/\/www.igt.nl\/wp-content\/uploads\/721.000_AMS-P_rvs_1-1.jpg","datePublished":"2020-03-20T06:00:37+00:00","dateModified":"2025-11-12T12:47:32+00:00","description":"IGT Amsterdam P is especially designed for QC purposes, it is prepared to do in-line analysis of Pick: IGT ISO 3783. Additionally IGT Roughness.","breadcrumb":{"@id":"https:\/\/www.igt.nl\/sg\/product\/ams-p\/#breadcrumb"},"inLanguage":"sg-SG","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.igt.nl\/sg\/product\/ams-p\/"]}]},{"@type":"ImageObject","inLanguage":"sg-SG","@id":"https:\/\/www.igt.nl\/sg\/product\/ams-p\/#primaryimage","url":"https:\/\/www.igt.nl\/wp-content\/uploads\/721.000_AMS-P_rvs_1-1.jpg","contentUrl":"https:\/\/www.igt.nl\/wp-content\/uploads\/721.000_AMS-P_rvs_1-1.jpg","width":700,"height":700},{"@type":"BreadcrumbList","@id":"https:\/\/www.igt.nl\/sg\/product\/ams-p\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.igt.nl\/sg\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/www.igt.nl\/sg\/shop\/"},{"@type":"ListItem","position":3,"name":"Paper Testers","item":"https:\/\/www.igt.nl\/sg\/product-categorie\/paper-testers-sg\/"},{"@type":"ListItem","position":4,"name":"Amsterdam","item":"https:\/\/www.igt.nl\/sg\/product-categorie\/paper-testers-sg\/amsterdam-sg\/"},{"@type":"ListItem","position":5,"name":"Amsterdam P"}]},{"@type":"WebSite","@id":"https:\/\/www.igt.nl\/sg\/#website","url":"https:\/\/www.igt.nl\/sg\/","name":"IGT Testing Systems","description":"","publisher":{"@id":"https:\/\/www.igt.nl\/sg\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.igt.nl\/sg\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sg-SG"},{"@type":"Organization","@id":"https:\/\/www.igt.nl\/sg\/#organization","name":"IGT Testing Systems","url":"https:\/\/www.igt.nl\/sg\/","logo":{"@type":"ImageObject","inLanguage":"sg-SG","@id":"https:\/\/www.igt.nl\/sg\/#\/schema\/logo\/image\/","url":"https:\/\/www.igt.nl\/wp-content\/uploads\/logo-igt-nieuw-450.webp","contentUrl":"https:\/\/www.igt.nl\/wp-content\/uploads\/logo-igt-nieuw-450.webp","width":451,"height":61,"caption":"IGT Testing Systems"},"image":{"@id":"https:\/\/www.igt.nl\/sg\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.igt.nl\/sg\/wp-json\/wp\/v2\/product\/21184","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.igt.nl\/sg\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.igt.nl\/sg\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.igt.nl\/sg\/wp-json\/wp\/v2\/comments?post=21184"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.igt.nl\/sg\/wp-json\/wp\/v2\/media\/21185"}],"wp:attachment":[{"href":"https:\/\/www.igt.nl\/sg\/wp-json\/wp\/v2\/media?parent=21184"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.igt.nl\/sg\/wp-json\/wp\/v2\/product_brand?post=21184"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.igt.nl\/sg\/wp-json\/wp\/v2\/product_cat?post=21184"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.igt.nl\/sg\/wp-json\/wp\/v2\/product_tag?post=21184"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}